A. Introduction:
This tester can test thermoplastic melt mass flow rate(MFR) and melt volume flow rate(MVR), YM-R0301 build-in ISO/ASTM standards test methods, operative picture is adopted touch panel guided conversation style screen, user can precisely and smoothly to proceed with test, build-in analysis function and with flash drive save function.
Optional accessories can be selected according to different materials properties, such as high flow materialblock mechanism or MVR displacement test mechanism to proceed with various tests.
Melt Flow Index confirms to ASTMD1238 D3364、ISO1133,GB- T3682 Standard
B. Photo reference:
C. Specification:
|
Use temperature |
50~360℃ |
|
|
Test Temperature, T |
Maximum allowable deviation from required test temperature |
|
|
At (10±1) mm above the top surface of the standard die |
From (10±1) mm to (70±1) mm above the top surface of the standard die |
|
|
125 ≦T<250 |
±1℃ |
±2℃ |
|
250 ≦T<300 |
±1℃ |
±2.5℃ |
|
300 ≦T |
±1℃ |
±3℃ |
|
Counter accuracy |
±0.01s |
|
|
Piston push rod weight |
100g |
|
|
Automatic cut |
Interval time 1-300 seconds can be set |
|
|
Heater size |
9.55±0.01mm |
|
|
Hole mold |
2.095±0.005mm |
|
|
Counter weight |
Stainless steel 1100g、2060g、3700g、4900g for each |
|
|
Accessories |
Cleaning brush、measuring cups、funnel and Die calibrationplug gauge |
|
|
Weight |
30 kg |
|
|
Dimension |
38x47x47cm |
|
|
Optional |
High MI value material blockmechanism, MVR test mechanism. |
|